ASME B16.9 ASTM A815 GR.2205 Welded Stub End DN350 Schedule STD
Short Description
Model No.: GR.2205-Welded-Stub-End-DN350-Schedule-STD
China Welded Stub End Manufacturer www.pipelinedubai.com offers ASME B16.9 ASTM A815 GR.2205 Welded Stub End, DN350, Schedule STD.
Key Specifications / Features
Type: 2205 Welded Stub End
Material: F51 (2205/UNS S31803/UNS S32205)
Size: 14″ (DN350)
WT: SCH STD
Standard: ASME B16.9
Chemical Composition – 2205(UNS S31803/Alloy 1.4462)
Grade |
C |
Mn |
Si |
P |
S |
Cr |
Mo |
Ni |
N |
|
2205 (S31803) |
Min Max |
– 0.030 |
– 2.00 |
– 1.00 |
– 0.030 |
– 0.020 |
21.0 23.0 |
2.5 3.5 |
4.5 6.5 |
0.08 0.20 |
2205 (S32205) |
Min Max |
– 0.030 |
– 2.00 |
– 1.00 |
– 0.030 |
– 0.020 |
22.0 23.0 |
3.0 3.5 |
4.5 6.5 |
0.14 0.20 |
NPS | OD | T | G | F | R | kg |
4 | 114.3 | 6.02 | 157.2 | 152.4 | 11.11 | 3 |
5 | 141.3 | 6.55 | 185.7 | 203.2 | 11.11 | 5.4 |
6 | 168.3 | 7.11 | 215.9 | 203.2 | 12.70 | 7.3 |
8 | 219.1 | 8.18 | 269.9 | 203.2 | 12.70 | 11.6 |
10 | 273.1 | 9.27 | 323.9 | 254 | 12.70 | 18 |
12 | 323.9 | 9.53 | 381 | 254 | 12.70 | 21 |
14 | 355.6 | 9.53 | 412.8 | 304.8 | 12.70 | 28 |
16 | 406.4 | 9.53 | 469.9 | 304.8 | 12.70 | 34 |
18 | 457.2 | 9.53 | 533.4 | 304.8 | 12.70 | 39 |
20 | 508 | 9.53 | 584.2 | 304.8 | 12.70 | 44 |
24 | 609.6 | 9.53 | 692.2 | 304.8 | 12.70 | 57 |
Dimensions are in millimeters unless otherwise indicated. Weights are in kilograms and approximately given.
DIMENSIONAL TOLERANCES OF STUB ENDS ASME B16.9
Nominal Pipe Size | 1/2 up to 2.1/2 | 3 to 3.1/2 | 4 | 5 to 8 | 10 to 18 | 20 to 24 |
Outside Diameter at Welding End (OD) |
+ 1.6 – 0.8 |
1.6 | 1.6 |
+ 2.29 – 1.6 |
+ 4.06 – 3.05 |
+ 6.35 – 4.83 |
Overall Length (F) | 1.6 | 1.6 | 1.6 | 1.6 | 2 | 2 |
Outside Diameter of Lap (G) |
+ 0 – 0.76 |
+ 0 – 0.76 |
+ 0 – 0.76 |
+ 0 – 0.76 |
+ 0 – 1.6 |
+ 0 – 1.6 |
Thickness of Lap (T) |
+ 1.52 – 0 |
+ 1.52 – 0 |
+ 1.52 – 0 |
+ 1.52 – 0 |
+ 1.52 – 0 |
+ 1.52 – 0 |
Fillet Radius of Lap (R) |
+ 0 – 0.76 |
+ 0 – 0.76 |
+ 0 – 1.6 |
+ 0 – 1.6 |
+ 0 – 1.6 |
+ 0 – 1.6 |
Wall Thickness (t) | Not less than 87.5% of Nominal Wall Thickness |
Dimensional tolerances are in millimeters unless otherwise indicated.